What is an LV Cable Joint?

Low voltage (LV) cable joints are accessories used on cables up to 1 kV to maintain insulation, provide strain relief and protect against moisture and mechanical damage wherever a cable is cut and reconnected.  They are used on armoured and unarmoured power cables, control cables and industrial wiring in applications such as utilities, infrastructure, manufacturing, rail and building services.

A complete joint kit typically includes mechanical or crimp connectors, insulation and sealing components (heat shrink, cold shrink or a resin mould), earthing and armour continuity parts, plus tapes or mastics for additional sealing.  Jointing systems are type‑tested to standards such as BS EN 50393 and rated 1000 V for LV distribution networks.

Types of LV Cable Joint: Overview

The three main jointing technologies used on LV networks are heat shrink, cold shrink and resin‑filled joints.

  • Heat shrink joints: heat-activated polymer tubes and moulded parts that shrink to tightly wrap around the cable, forming a tight seal and insulating the connection.
  • Cold-shrink joints: pre-expanded rubber sleeves contract around the cable when a removable core is removed, providing a constant radial pressure seal with no heat.
  • Resin joint: apply two-part insulating resin into a mould to the connection, which will harden to form a solid, waterproof, mechanically strong block.

JointingTech’s LV range covers all three technologies for straight and branch joints, hazardous-area joints, and specialist rail/industrial applications.

Heat Shrink LV Cable Joints

Heat shrink LV joints are among the most widely used solutions for armoured and unarmoured cables in industrial and utility environments.

How heat shrink joints work

Heat shrink joints use factory‑expanded polymer tubes and moulded breakouts that shrink when heated with a gas torch, gripping the cable sheath and core insulation. The jointer prepares and connects the conductors, reinstates the bedding and armour with cages or screens, then shrinks the outer tubes and liners to restore insulation and provide a moisture‑tight seal.

This technology is suitable for:

  • Straight joints on LV armoured multicore cables.
  • Multipair and multicore telephone, control and signalling cables.
  • Vertical and horizontal installations in indoor and outdoor environments.

Key features and benefits

Heat shrink LV joint kits from manufacturers such as Tyco (Raychem) are designed specifically for LV armoured cables and typically offer:

  • Excellent electrical insulation from insulating tubes and liners.
  • High mechanical strength via armour cages and reinforced outer sleeves.
  • Simple and fast installation with no curing time, allowing immediate backfill.
  • 1000V rating and testing to BS EN 50393 for performance assurance.
  • Wide operating temperature range, commonly from −50 °C to +50 °C.

Zero‑halogen heat shrink tubes are available for rail and tunnel applications where low smoke and toxicity are critical.

Typical applications

Heat shrink LV joints are a good fit where:

  • A proven, cost‑effective technology is required for standard LV distribution circuits.
  • There is safe access for a gas torch and open flame.
  • Immediate backfill is needed (e.g. civil works, utility trenching).
  • Armoured cable continuity and robust mechanical protection are important (industrial, rail, substation and street lighting networks).

Cold Shrink LV Cable Joints

Cold shrink joints deliver similar electrical and environmental performance to heat shrink joints but without the need for a heat source.

How Cold Shrink Joints Work

The cold-shrink technology involves pre-stretched silicone or EPDM rubber sleeves attached to a removable inner core.  The sleeve is placed over the prepared cable joint, and upon pulling the core out, the sleeve elastically contracts around the cable and connectors, providing continuous radial pressure.

LV armoured and unarmoured cables can also have straight cold shrink joints, which are intended to connect inline joints where a cold applied system is desirable.  They re-insulate and seal the environment without gas torches or appropriate hot-work permits.

Key features and benefits

Cold shrink joints typically offer:

  • No heat needed, enhances security in tight or unsafe spaces.
  • Constant pressure of sealing the tube under elastomeric tubes, which is able to withstand thermal cycling and vibration.
  • Quick, easy to install and fewer tools than certain heat shrink systems.
  • Dependable moisture protection and insulation of LV distribution and control circuits.

Typical applications

The cold shrink LV joints are mostly used when:

  • Labour under constant pressure, in the underground areas or other buildings with combustibles, where open fires are not allowed.
  • Installation which need speed and repeatability (large rollout programmes, repetitive jointing).
  • The long-term performance of sealing is essential when thermal and mechanical stresses are considered, e.g., in rail, offshore, and industrial installations.

Resin-Filled LV Cable Joints

The LV cable connection is enclosed in a solid, cast resin block to provide the greatest protection for the joint.

How Resin Joints Work

Resin joint kits use a two-part polyurethane or epoxy resin, sold in a closed mixing and pouring system, usually in a two-chamber bag.  Breaking the separator in the bag, the resin is poured into a one-piece mould around the prepared joint until full.  Once cured, the resin becomes a stiff, insulating coating of the cables and connectors.

These joints will be used on LV power cables and are specifically intended for high-mechanical protection and watertight joints in harsh conditions.

Key features and benefits

Resin LV joints offer:

  • Superior protection against moisture ingress, chemicals and mechanical impact.
  • Robust encapsulation suitable for underground, direct‑buried and submerged applications.
  • Flexible selection of resin hardness, gel‑time and temperature rating to suit installation conditions.
  • Closed mixing and pouring systems to reduce mess and improve safety during installation.

They are widely used in utilities, industrial plants and infrastructure projects where long‑term reliability in demanding environments is critical.

Choosing Between Heat Shrink, Cold Shrink and Resin

The best LV jointing method depends on the cable type, installation environment, access conditions and safety or regulatory requirements.

At‑a‑glance comparison

Factor

Heat shrink LV joints

Cold shrink LV joints

Resin LV joints

Installation method

Torch‑applied heat shrinks tubes and moulded parts tightly around cables.  

Pre‑stretched rubber sleeve contracts when core is removed, no heat needed.  

Two‑part resin mixed and poured into mould around joint, then cures solid.  

Cable types

LV armoured multicore, multipair and multicore control cables.  

LV armoured and unarmoured power and control cables.  

LV power and control cables in harsh or buried environments.  

Mechanical protection

High, via armour cage and tough outer sleeve.  

High, elastomeric sleeve with good flexibility and impact resistance.  

Very high; solid resin block resists impact, compression and abrasion.  

Moisture sealing

Excellent when correctly shrunk and sealed.  

Excellent, constant radial pressure maintains seal.  

Outstanding, fully encapsulated and watertight.  

Tools and permits

Requires heat source and suitable hot‑work controls.  

No flame or heat; ideal where torches are restricted.  

Requires resin handling, mixing and curing time.  

Installation speed

Fast; no curing, immediate backfill possible.  

Fast; single motion core removal, no cure time.  

Slower; requires gel and cure time before backfill.  

Typical applications

General LV distribution, industrial, rail and building services, including vertical runs.

Confined spaces, hazardous areas, offshore, rail and utilities where flame‑free jointing is required.  

Direct‑buried and submerged joints, chemically aggressive or high‑impact environments in utilities and industry.  

 

Practical Selection Tips

  • For standard LV armoured cable joints where torches are permitted, and a proven, fast‑install solution is required, heat-shrink joints are usually the first choice.
  • For confined or hazardous environments where hot work is restricted, cold shrink LV joints provide a flame‑free alternative with excellent sealing performance.
  • For direct‑buried or submerged joints, or where high mechanical abuse or chemical exposure is expected, resin‑filled joints deliver the highest level of encapsulation and environmental protection.

JointingTech’s LV product range includes heat shrink, cold shrink and resin joint kits, along with specialist accessories such as hazardous area joints, shorting kits and insulation products, enabling you to match the jointing technology precisely to your installation conditions.